Starna

簡要描述:Starna,代理,科技(原Optiglass有限公司)成立于1964年,其光學(xué)知識(shí)譜系可以追溯到上世紀(jì)早期??萍加邢薰臼羌瘓F(tuán)的全資子公司。

  • 產(chǎn)品型號(hào):
  • 廠商性質(zhì):經(jīng)銷商
  • 更新時(shí)間:2024-08-29
  • 訪  問  量:2178

詳細(xì)介紹

 Starna,Starna代理,科技,所有的產(chǎn)品制造都是在其經(jīng)過ISO 9000認(rèn)證的生產(chǎn)裝置上進(jìn)行的,從產(chǎn)品的設(shè)計(jì)、開發(fā)到定制生產(chǎn)機(jī)械。*的一系列工藝,包括切割,切片,研磨,拋光,常規(guī)鉆井,超聲鉆削和融合,這些都使的生產(chǎn)實(shí)現(xiàn)了一個(gè)完整的垂直整合的過程。

The Fluorescent Materials
Sample
Number
Compound Approximate 
Molar Conc
Excitation
Wavelength
Emission
Wavelength
1 Anthracene 1 x 10-5 360 402
  Napthalene 6 x 10-5 290 330
2 Ovalene 2 x 10-7 342 482
3 p-Terphenyl 5 x 10-7 295 338
4 Tetraphenylbutadiene 3 x 10-7 348 422
5 Compound 610 1 x 10-6 440 475
6 Rhodamine 2 x 10-7 562 573

 

Care of the Reference Materials

The blocks are supplied in a velvet lined case to 
protect the fine surface finish produced at manufacture. Providing that they are handled with care (cotton gloves are recommended) and always stored in the case 
provided, they should give many years of satisfactory service. Exposure to organic solvents can cause severe fogging of the surface and must be avoided, as should any attempt to clean the block with abrasive cleaners.

In the event of the surface of a block becoming soiled, it should be immersed in dilute neutral detergent solution which may be warmed to 40°. Low power ultrasonic vibration may also be used to remove the contamination. It should then be rinsed thoroughly with deionized water and dried carefully with a soft lint-free cloth.

 

Recorded Spectra

The following spectra were recorded in the ratio 
mode, using a Perkin Elmer LS50B Luminescence Spectrometer. The spectral band width for both 
excitation and emission monochromators, was 2.5 nm. Data points were recorded at 0.5 nm intervals. These spectra are specific to this instrument and the operating conditions used. Other instruments, or different 
operating conditions will produce spectra with maxima which may vary both in terms of relative magnitude and wavelength.

The corrected Spectra were recorded using a Perkin Elmer MPF44-B and should relate to others recorded in a similar manner.

產(chǎn)品咨詢

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說明:

  • 驗(yàn)證碼:

    請輸入計(jì)算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7
上海起發(fā)實(shí)驗(yàn)試劑有限公司
地址:上海浦東川沙鎮(zhèn)川沙路6619號(hào)上海起發(fā)實(shí)驗(yàn)試劑有限公司
郵箱:xs1@78bio.com
傳真:021-50724961
關(guān)注我們
歡迎您關(guān)注我們的微信公眾號(hào)了解更多信息:
歡迎您關(guān)注我們的微信公眾號(hào)
了解更多信息